-40%
EPD-23420A 8 conductor cable
$ 5108.39
- Description
- Size Guide
Description
your are bidding/buying TE connectivity cable # EPD23420A at a price of .45/ft please (can part out) see info below (on pictures) this is new overstock and comes with manufacturers certicfications;ships in US only
Components
ID Quantity Part number Description
A 8 44A0111-20 Primary wire
B 1 FIL-40-0.090 Solid Thermorad Filler 0.090 OD
Cable
Outer Description Thickness OD
Inches mm Inches mm
Layer 1 0.203 5.16
Jacket Thermorad NTFR black 0.048 1.22 0.299 7.60
Cable OD tolerance + 0.016 + 0.40
- 0.016 - 0.40
Specification Raychem WCD 3314
Weight 60.40 lb/kft 90.05 Kg/Km
Physical properties
Component Sequence The placing of the components in the cross sectional view of the cable is for
reference only and is not a requirement
Notes
Colors Color code designators shall be in accordance with MIL-STD-681.
Dimensions Dimensions are in inches, and unless otherwise designated, are nominal.
Export License Note These commodities, technology, or software must be exported from the United
States in accordance with the Export Administration Regulations. Diversion contrary
to U.S. law is prohibited.
Identification, Colors & Marks The following is the key to the descriptions in the left hand view of the cable on page1
Line 1: Identifies the component per the components' ID list.
Line 2: Color codes.
Line 3: Mark on component "-" mark on component jacket.
Minimum length Cable will be supplied in 50 ft. minimum lengths unless otherwise specified.
Part Number Note Other codes and suffixes may be added to the Part Number as necessary, to
capture any additional requirements imposed by the purchase order
Specification Information This drawing is the property of Tyco Electronics Corporation and may not be used
for any purpose other than for that which it is supplied without the express written
authority of Tyco Electronics Corporation.
Trademarks Raychem, Thermorad , TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
Color scheme Number sequence.
Note This is an Americanized UK EPD, testing to the US WCD specification.